JCTLM Database: higher-order reference materials, methods and services
Details : C16RMS29 - sodium in Blood serum, Blood plasma
| Type (acronym) | rms |
| Type | reference measurement service |
| Unique Nomination Number | C16RMS29 |
| Reference Laboratory Status | Manufacturer |
| Analyte Name | sodium |
| IUPAC IFCC Number | CAS7440-23-5 |
| Applicable Matrices | human fresh, frozen or lyophilized human serum |
| Traceable to SI | Yes |
| Principle of Analytical Procedure | High resolution ICP/MS |
| Reference Method Listed in JCTLM | Yes |
| Name of JCTLM Listed Reference Method Procedure | NCCL ICP-MS reference measurement procedure for serum sodium |
| JCTLM Database Identifier Number | C14RMP9 |
| Procedure Difference in Your Laboratory | No |
| Quantity | Amount of substance concentration |
| From (0) | 117.4 |
| To (0) | 157.1 |
| Unit (0) | mmol/L |
| From (1) | 1 |
| To (1) | 1 |
| Unit (1) | % |
| Level of Confidence (%) | 95% |
| Comments on Uncertainty Range | The expanded
uncertainty is relative uncertainty |
| Survey Organisation | RELA - IFCC External
Quality assessment
scheme for Reference
Laboratories in
Laboratory Medicine |
| Intercomparison Results Publicly Available | Yes |
| Link to Comparison Results | RELA - IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine at AND http://www.dgkl-rfb.de:81/index.shtml |
| Reference to Published Comparison Results |
The code of this laboratory in RELA - IFCC EQAS is 51. |
| Organization Acronym | Maccura |
| Organization Name | Maccura Biotechnology Co., Ltd. Reference System Dept. |
| Organization Website | https://www.maccura.com/en/ |
| Organization Country ISO Code | CN |
| Organization Country Name | China |
| Analyte Category Name | Electrolytes |